Most facility’s compressed air systems have evolved over time. A spur added here a spur added there. Eventually pressure drop issues develop. Common practice is to increase the air pressure at the compressor. While it may address the symptom it does not address the problem and is very costly. For every 2 PSI increase in pressure requires 1% more energy.

A properly designed system will be a loop with spurs. This will ensure all airsystem

drops will share the air equally. The header loop should be able to carry all the air the compressor is capable of producing.  Best practices suggest the distribution header should be sized to allow an air velocity not to exceed 30 ft/second. The formula to calculate this is:

A =    144 * Q * Pa
       V *60 x (Pd +Pa)

Pipe Diameter = √ (A*4/3.14)

Where:

A = cross sectional area if the pipe bore in square…

View original post 133 more words